Welcome to www.aakindustry.com

With a small good trick, AAK Hydraulic Cartridge Relief Valve replaced HydraForce standard part

Views : 132
Update time : 2023-03-23 11:07:39

Cyrano, an experienced buyer of hydraulic cartridge valves from Greece, encountered difficulties with a batch of hydraulic cartridge relief valves. At the beginning of the year, they developed a hydraulic power unit and used a hydraulic cartridge relief valve purchased from a hydraulic cartridge valve manufacturer in Ningbo. During the commissioning of the hydraulic power unit, the operation was not stable. Their engineer found that when the overflow flow rate changes greatly, it is easy to cause a large change in the pressure at the inlet of the hydraulic cartridge relief valve. The original manufacturer reported that this hydraulic direct-acting relief valve is a standard part benchmarking HydraForce, they should have their engineer to control the system's overflow flow fluctuations, which embarrassed Cyrano.

 

Cyrano found AAK on Google and noticed that AAK has had multiple cases of solving difficult and complex problems for customers. He emailed us to ask, "How to improve the stability of HydraForce's standard hydraulic direct-acting relief valve?". This question is too big to answer. After communication, it was learned that he had encountered a problem matching the standard part of the hydraulic cartridge relief valve with his equipment. The direction is clear, but whether to choose to optimize A to match B or optimize B to match A, there are only these 2 options.

 

AAK engineer asked if it is possible to replace the hydraulic direct acting relief valve with a pilot operated relief valve? AAK can design according to the working conditions. He paid the development fee the next day, and 40 days later, AAK sent samples of the hydraulic cartridge relief valve. Last week, Cyrano informed that after AAK hydraulic cartridge relief valve was installed in the system, when the overflow flow changed significantly, the pressure at the inlet of the hydraulic relief valve did not change much. Their engineers were very happy and there would be no need to change the system.

 

AAK hydraulic pilot operated relief valve can replace HydraForce hydraulic direct acting relief valve, which is actually very simple. The pilot valve and the main valve are combined to form a whole. The pilot valve controls and regulates the overflow pressure, and the main valve functions as an overflow valve. The two ends of the main valve plug are subjected to oil pressure. The main valve pressure spring is made of small stiffness material. When the overflow flow rate changes greatly, the compression amount of the pressure spring does not increase, and the pressure at the oil inlet is stable.

 

1. AAK hydraulic pilot operated relief valve is equipped with a first liquid chamber and a cavity for installing the valve spool. The first liquid chamber and the cavity are connected through a through hole. One end of the valve spool is located in the through hole, and the other end is connected to a pressure regulating device, which is fixed on the valve body.

 

2. The main valve seat is provided with an oil inlet and a return port, which are connected to the oil return port. The plug plugs the oil inlet and return ports through their ends and sides, respectively. The plug connects to the valve body through a pressure spring, and the plug has a damping hole.

 

3. The pressure regulating device consists of a pressure regulating screw and a spring. One end of the pressure regulating screw is connected to the spring, and the other end of the pressure regulating screw is connected to the valve body. The end face of the plug plugged into the oil inlet is a conical surface.

 

AAK hydraulic cartridge pilot operated relief valve, high stability, you can also try it!

 

AAK HYDRAULIC CARTRIDGE VALVES (539) 2023-03-23

Related News
Read More >>
The trial order for hydraulic manifold blocks cannot be completed within 50 days by peer, but hydraulic manifold manufacturer AAK solved it in 30 days The trial order for hydraulic manifold blocks cannot be completed within 50 days by peer, but hydraulic manifold manufacturer AAK solved it in 30 days
Dec .07.2023
Asa from Israel contacted me a while ago. This guy hasn't contacted hydraulic manifold manufacturer AAK for 3 months. I realized he was facing difficulties before I opened the email.
AAK accurate 100% full inspection to ensure customized hydraulic cartridge relief valve function & service life AAK accurate 100% full inspection to ensure customized hydraulic cartridge relief valve function & service life
Dec .06.2023
For RV10-26 hydraulic cartridge relief valve with two major requirements, AAK solved the troubles of Kuzma from two problems
1 for 5 testing equipment, AAK solved the delivery time problem that Mablevi encountered on hydraulic pressure control valve 1 for 5 testing equipment, AAK solved the delivery time problem that Mablevi encountered on hydraulic pressure control valve
Dec .05.2023
Mablevi is from Turkey. In early November, he left a message on the hydraulic cartridge valve manufacturer AAK website: Can you deliver 200 pcs of hydraulic pressure control valves within 20 days, equivalent to HydraForce RV08-22?
For Hydraulic Cartridge Relief Valve equivalent to SUN RDDA, a Russian customer placed the order on the spot at AAK factory For Hydraulic Cartridge Relief Valve equivalent to SUN RDDA, a Russian customer placed the order on the spot at AAK factory
Dec .04.2023
This week, we’d like to introduce a hydraulic cartridge relief valve equivalent to SUN RDDA. This Direct-acting relief cartridge is normally closed, pressure-limiting valve used to protect hydraulic components from pressure transients.