Welcome to www.aakindustry.com

The original hydraulic valve manufacturer cannot meet the accuracy of valve hole 1.0μm for hydraulic flow control valves, AAK achieved 0.8μm

Views : 282
Update time : 2022-08-05 11:17:30

In March this year, Danielisadora, a Brazilian customer, sent us an inquiry, urgently needing 20 non-standard customized hydraulic flow control valves with an accuracy of 1.0μm valve hole, which is required to be completed within 1 month. Danielisadora has not cooperated much with AAK. Previously, he purchased some SUN hydraulic valves in small quantities but with high requirements. For 20 small quantities of non-standard customized hydraulic flow control valves, most hydraulic valve manufacturers were unwilling to do. After several rounds of email communication, we learned the difficulties that Danielisadora has met.

 

In the second half of last year, Danielisadora developed a high-performance excavator, which needs a high-precision hydraulic control system as a support, reflecting the high-speed, heavy load and accurate displacement of the equipment. However, the equipment is not smooth in the commissioning stage, and the buffers at both ends of the excavator stick cylinder often fail. Their engineer was puzzled. After disassembling the hydraulic system, it was found that there was a little leakage in the hydraulic flow control valves on the oil cylinder, which was caused by the valve hole accuracy of the hydraulic flow control valves exceeding 1.0μm. The boss asked Danielisadora to solve the problem quickly, because it will miss the exhibition period after 50 days. According to the feedback of the original manufacturer of hydraulic flow control valves, he has no ability to meet the accuracy standard of the 1.0μm valve hole now and has to give up. Danielisadora was helpless. 1 week passed, no manufacturer is willing to try the order of hydraulic flow control valves. The boss had pushed the progress twice, and Danielisadora was under great pressure.

 

Danielisadora sent me an email and urgently needed 20 non-standard customized hydraulic flow control valves with the accuracy of 1.0μm valve hole. He said that the SUN hydraulic valves shipped by AAK have never been complained about its accuracy. Frankly speaking, the 1.0μm valve hole accuracy of hydraulic flow control valves is not too difficult for AAK. After 30 days, 20 high-precision hydraulic flow control valves were delivered. Half a month later, Danielisadora informed that AAK hydraulic flow control valves were installed on the equipment, and the equipment abnormality happened last time was solved. Now the equipment commissioning was successful, and the valve hole accuracy of AAK hydraulic flow control valves was all 0.8μm, while the other hydraulic valve manufacturers connect meet the accuracy standard of even 1.0μm.

 

AAK has owned a high-precision honing machine imported from Switzerland as early as 3 years ago, and is equipped with HDK diamond reamer. This reamer is especially skilled in high precision. The roundness of the front and rear guide is 0.005mm, the cylindricity is 0.005mm/100mm, and the roughness of the front guide is Ra0.63μm. Roughness of rear guide excircle Ra0.16μm. The coaxiality between the tool handle and the front and rear guide parts reaches 0.015mm; Therefore, the aperture accuracy of the machined workpiece can be guaranteed to be within 0.8μm, the surface roughness of reaming the aperture of hydraulic flow control valves can reach Ra0.2. A few hydraulic valve manufacturers may have high-end processing equipment, but for those with HDK diamond reamers, there will never be a third one in Ningbo.

 

Danielisadora privately informed that the boss now attaches great importance to him, and he is responsible for all the purchases with some difficulties. AAK Hydraulic Valves is now his preferred hydraulic valve manufacturer for cartridge valves.

 

AAK hydraulic flow control valves, with valve hole accuracy within 0.8μm, and 3drops/min, benchmarking with HydraForce quality, there are few rivals, you can also have a small try!

 

AAK HYDRAULIC CARTRIDGE VALVES (309) 2022-08-05

Related News
Read More >>
Piloted directional valve equivalent to HydraForce PD10-41 passed testing, AAK received the more inquiries from customer in the United States Piloted directional valve equivalent to HydraForce PD10-41 passed testing, AAK received the more inquiries from customer in the United States
Apr .15.2024
Last July, we shipped a Piloted Directional Valve equivalent to HydraForce PD10-41 to a customer in the United States.
For Pilot-Operated Pressure Reducing/Relieving Valve equivalent to SUN PPDB-LDN, AAK received the re-peat order from customer in Europe For Pilot-Operated Pressure Reducing/Relieving Valve equivalent to SUN PPDB-LDN, AAK received the re-peat order from customer in Europe
Apr .09.2024
Last April, we shipped a Pilot-Operated Pressure Reducing/Relieving Valve equivalent to SUN PPDB-LDN to a customer in Europe.
For Hydraulic Flow divider/combiner valve equivalent to HydraForce FD50-45, AAK received the trial order from a Customer in the United States For Hydraulic Flow divider/combiner valve equivalent to HydraForce FD50-45, AAK received the trial order from a Customer in the United States
Apr .01.2024
This week, we’d like to introduce a hydraulic flow divider/combiner valve equivalent to HydraForce FD50-45.
For Hydraulic Pilot-to-close check valve equivalent to SUN COJA, AAK received the trial order from a Customer in Germany For Hydraulic Pilot-to-close check valve equivalent to SUN COJA, AAK received the trial order from a Customer in Germany
Mar .25.2024
This week, we’d like to introduce a hydraulic Pilot-to-close check valve equivalent to SUN COJA. This valve is a spring biased closed, pilot-to-close check cartridge that has a 1.8:1 pilot ratio.