Problem of hydraulic directional control valve continues after changing 3 factories, AAK adjusted integrated design and solved it in less than 30 days

Views : 352
Update time : 2022-03-29 11:05:07

One morning last month, Antonio emailed us that there was a problem with AAK hydraulic directional control valves purchased some time ago, and a problem was found in the factory commissioning of the bending machine. The starting pressure of the hydraulic system of the bending machine will suddenly increase. Their engineers think it is caused by the instability of the hydraulic direction control valves and ask us to replace it. I'm totally confused. Because this hydraulic directional control valve is produced and inspected in full accordance with the parameters provided by Antonio, and the parameters of the hydraulic directional control valve are approved in the commissioning stage of the bending machine.

 

Antonio is from Prada Nargesa company in Spain. He has cooperated with AAK on hydraulic directional control valves for several years. This is the first complaint from him. In the sample stage, Antonio informed that this hydraulic direction control valve was used in the hydraulic system of the bending machine produced by his company. It was noted that the bending tonnage was required to be 400 tons, the maximum bending length was 6 meters, and the bending accuracy was +/- 0.3°. The pressure and accuracy requirements of the hydraulic direction control valve were very high. After our internal discussion, we found the problem strange.

 

AAK engineer asked Antonio to send a video of the working condition of the hydraulic system of the bending machine for us to check what the problem is. Through the video, we found that there was a problem about the installation position of the needle valve of the integrated valve block of the hydraulic system and the position of the hydraulic directional control valve. It was preliminarily judged that the pressure regulation mode of the hydraulic system of the bending machine is not correctly designed, and this hidden danger will come out after more than 8 hours of continuous test run. But the designers of their company didn't agree with our proposal and thought we were shifting the responsibility.

 

I suggest Antonio give us 30 days to redesign the integrated valve block. If there are still problems after installation, AAK is willing to bear all costs. Considering that these bending machines are in a hurry to ship, it will take longer time if purchasing new hydraulic directional control valves, moreover it is not guaranteed that the new hydraulic directional control valves will be no problem, Antonio reluctantly agreed with AAK proposal. After 25 days, AAK sent out the integrated valve block with hydraulic directional control valve, which was installed and debugged for more than 8 hours. Everything of the bending machine was normal, and their designers had to affirm it.

 

AAK professional engineers designed the pressure regulation of the hydraulic system of the bending machine as a modular type, and rearranged the position of the needle valve and the hydraulic direction control valve, so as to provide the proportional regulation function. At the same time, the unloading circuit is simple and reliable. The safety pressure valve is connected in parallel in the lower chamber of the oil cylinder to form a double safety circuit to prevent the abnormal rise of the oil pressure in the lower chamber from damaging the oil cylinder and pipeline, so as to ensure the safety of the equipment.

 

Antonio told us privately that a similar situation happened the year before last. The hidden danger of the original design of the equipment is simply considered to be the problem of the supplier's hydraulic directional control valve. Even they changed 3 manufacturers of hydraulic directional control valves, problem was still not solved.

 

AAK hydraulic directional control valve can give technical support that peers can't give. You are welcome to have a try!

 

AAK HYDRAULIC VALVE (180) 2022-03-29

Related News
Read More >>
For Proportional Priority Flow Control Valve Cartridge equivalent to HydraForce PV72-30, Brazilian customer has been purchasing it from AAK since 2022 For Proportional Priority Flow Control Valve Cartridge equivalent to HydraForce PV72-30, Brazilian customer has been purchasing it from AAK since 2022
Dec .02.2024
In June of 2022, a Brazilian customer placed the test order from AAK for an Electro-Proportional Priority Flow Regulator Valve Cartridge equivalent to HydraForce standard part PV72-30.
For Hydraulic Flow Control Valve equivalent to SUN FDCB, a few Brizilian customer placed the bulk order with AAK For Hydraulic Flow Control Valve equivalent to SUN FDCB, a few Brizilian customer placed the bulk order with AAK
Nov .25.2024
In March of this year, a new Brazilian customer placed a trial order for a hydraulic flow control valve equivalent to SUN FDCB with AAK.
For Solenoid Cartridge Valve equivalent to HydraForce SF08-23, a few customers placed the trial order with AAK recently For Solenoid Cartridge Valve equivalent to HydraForce SF08-23, a few customers placed the trial order with AAK recently
Nov .18.2024
Two weeks ago, a new Italian customer placed the test order for a hydraulic solenoid cartridge valve equivalent to HydraForce SF08-23 with AAK.
For Proportional Flow Control Cartridge Valve equivalent to HydraForce PV07-30, AAK has exported to several countries For Proportional Flow Control Cartridge Valve equivalent to HydraForce PV07-30, AAK has exported to several countries
Nov .11.2024
In 2022, a Brazilian customer placed the test order with AAK for a Proportional Flow Control Cartridge Valve equivalent to HydraForce PV70-30.