SYMBOL
OPERATION
Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.
SPECIFICATIONS:
Working Pressure: 350 bar (5000 psi)
Flow Rating: 120 lpm (30 gpm)
Maximum Valve Leakage at Reseat: 3 in³/min.
Response Time - Typical: 25 ms
Cavity: T-2A
Installation Torque: 60 - 70 Nm
Temperature Range: - 30 °C ~ +120 °C (with Buna N seals)
Filtration: 25μm or better
Fluids: Mineral-based fluids with viscosities of 7.4 to 420 cSt.
PERFORMANCE:
DIMENSIONS
ORDER CODE:
AAK Hydraulic Valve is a top manufacturer for Hydraulic Cartridge Sequence Valves in Ningbo China since 2009.
We guarantee quality for 3 years for non-standard customized valves: No leakage, No Noise, No Vibration.
Contact us to customize your valves and promote your business with our premium quality!