E-PC10-30 PILOT OPERATED CHECK VALVE
SYMBOL
DESCRIPTION
The E-PC10-30 is a screw-in, cartridge style, pilot operated, hydraulic check valve used for blocking or load holding circuits.
OPERATION
E-PC10-30 allows free flow from port 2 to 3, while normally blocking flow from port 3 to 2. Flow will be allowed from port 3 to 2 when pressure is applied at port 1. The pilot ratio of the check valve is 4:1, which means that the pressure at port 1 should be at least 1/4 of the load pressure at port 3 before the valve can be opened. Under static or no load conditions, the spring pressure ensures that the valve port is closed. Hydraulic piston with seal is available.
FEATURES:
l Hardened seat for long life and low leakage.
l Optional sealed piston.
l Optional spring ranges.
l Compact size.
SPECIFICATIONS:
Working Pressure: 240 bar (3500 psi)
Flow Rating: see performance chart.
Maximum Internal Leakage:
0.10 ml/min (2 drops/min) Between ports 3 and 2
115 ml/min (7 in³/min) Between ports 2 and 1
0 ml/min (0 drops/min) Between ports 2 and 1 with sealed piston
Pilot ratio: 4:1
Temperature Range: - 40 to 120 °C (with Buna N seals)
Filtration: Best working fluid cleanliness ≥ NAS Class 9
Fluids: Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range: 7.4 to 420 cSt (50 to 2000 ssu)
Cavity: VC10-3;
Seal kit: SK10-3X-TM
PERFORMANCE:
DIMENSIONS:
ORDER CODE:
AAK Hydraulic Valve is a top manufacturer for Hydraulic Cartridge Check Valves in Ningbo China since 2009.
We guarantee quality for 3 years for non-standard customized valves: No leakage, No Noise, No Vibration.
Contact us to customize your valves and promote your business with our premium quality!